Skip to content Skip to navigation
UMass Collegiate M The University of Massachusetts Amherst
  • Visit
  • Apply
  • Give
  • Search UMass.edu
Center for Agriculture, Food, and the Environment
UMass Extension Greenhouse Crops and Floriculture Program
  • Floriculture Home
  • About
    • About Greenhouse Crops and Floriculture
    • Contact Information
  • Fact Sheets
  • Greenhouse Updates
    • Latest updates & Archive
    • Greenhouse Update Photo Library
    • E-Mail List
  • Publications & Resources
    • Newsletters
    • Greenhouse Best Management Practices (BMP) Manual
    • New England Greenhouse Floriculture Guide
    • Biological Control/Organic Information
    • Pesticide Information (Labels, MSDS, WPS)
    • Pesticide Licensing (Certification, Exams, Workshops)
    • Resources for Garden Retailers
    • Useful Links
    • Nutrient Management
    • Soil and Plant Nutrient Testing and Diagnostics
  • Education & Events
    • Upcoming Events
    • Northeast Greenhouse Conference
    • Webinars
  • Make a Gift

Water Analysis

Checklist: Water Analysis

  • Test water to be used for irrigation by a reputable laboratory to determine the quality of the water for irrigation, choice of fertilizers for optimum plant growth, and to minimize the risk of discharging pollutants to surface or ground water. At minimum, test for total alkalinity and soluble salts.
  • Test potential irrigation water prior to new construction. Monthly analysis is recommended for new water sources. Existing greenhouse operations should monitor water quality at least twice a year (summer and winter); more frequent monitoring is needed to alter production practices in response to changes in water quality.
  • When collecting a water sample, run the water at full flow for five minutes before collecting one pint of water in a tightly sealed plastic bottle. For best results, fill a clean 5 gallon bucket with water and submerge the sample bottle, then seal with the cap under water. Do not use metal lids. The bottle should be totally full with no air space remaining.

Water Analysis

Many factors taken together determine the quality of water for irrigation of plants. The chemical constituents of irrigation water can affect plant growth directly through toxicity or deficiency, or indirectly by altering plant availability of nutrients.

Water Analysis

Once the source of water is identified, water to be used for irrigation should be tested by a reputable laboratory to determine the quality of the water to be used for irrigation, to aid in the choice of fertilizers for optimum plant growth, and to minimize the risk of discharging pollutants to surface or ground water.

Prior to new construction, potential irrigation water should be tested. Monthly analysis is recommended for new water sources. Existing greenhouse operations should monitor water quality at least twice a year (summer and winter); more frequent monitoring is needed to alter production practices in response to changes in water quality.

Collecting a Water Sample

When collecting a water sample, run the water at full flow for five minutes before collecting one pint of water in a tightly sealed plastic bottle. For best results, fill a clean 5 gallon bucket with water and submerge the sample bottle, then seal with the cap under water. Do not use metal lids. The bottle should be totally full with no air space remaining.          

Testing by Laboratories

Analysis for inorganic elements should include electrical conductivity (soluble salts), pH, alkalinity, nitrate nitrogen, ammonium nitrogen, calcium, magnesium, sodium, potassium, phosphorus, zinc, copper and aluminum.

Testing water for pesticides, herbicides or fuel oil is very expensive, particularly if the contaminant is unknown.

Analysis for biological or disease organisms is not generally recommended since many plant pathogens are always present in water at some level.

A list of commercial greenhouse water testing laboratories is available under “Resources” at the end of the document.

On-Site Water Testing

Electrical conductivity and pH are two characteristics of water quality that can be tested periodically at the growing facility. This helps the grower get an indication of the consistency of the water supply and check the results of treatments to reduce pH or soluble salts. pH meters range from inexpensive pen types to more sophisticated units. It is recommended to purchase one that can be calibrated using calibration solutions. This ensures that the meter is giving correct readings. Electrical conductivity meters are generally more expensive than pH meters. However, they are very useful for testing water quality and media fertilizer levels during crop growth.

Table 1. Target range and Acceptable range of nutrients and other components of irrigation water
Note: The target range is desirable levels, while acceptable levels are broader.
  Target Range in ppm (parts per million) except for pH and EC (electrical conductivity) Acceptable Range (in ppm except for pH and EC) W
pH 5.5 to 7.0 4 to 10
EC 0.2 to 0.8 mS (milliSiemen) 0 to 1.5 mS (milliSiemen)
Sodium 0 to 20 < 50
Chloride 0 to 20 < 140
Alkalinity X 40 to 160 0 to 400
Ammonia N NA < 10
Boron < 0.1 < 0.5
Nitrate N Y NA < 75
Phosphate 0 to 3 < 5.0 z
Potassium NA < 100
Magnesium 10 to 30 < 50
Calcium 25 to 75 < 150
Sulfate 0 to 40 < 100
Manganese < 1.0 < 2.0
Iron < 1.0 < 4.0
Boron < 0.1 < 0.5
Copper < 0.1 < 0.2
Zinc < 0.5 < 0.3
Fluoride < 0.1 < 1.0
Molybdenum < 0.1 < 1.0

w No expected crop damage under average environmental conditions. Higher rates of macronutrients may lead to undesired plant growth as in the case of plugs. The acceptable limits for trace elements and fluoride are dependent on medium pH. These levels may be too high for growing medium pH less than 5.8.

x Usually depends on the volume of medium and volume of water applied. The medium pH with smaller volumes of media such as with plugs may be stable with 40 to 80 ppm while medium pH in larger pots with higher rates of fertilization may stabilize at 120 to 160 ppm.

y NA – Not applicable (Note: Levels of nitrate over 10 ppm may indicate a significant level of contamination and a health hazard in drinking water.)

z P levels above 5 ppm can interfere with plant uptake of other nutrients and can also be an indicator of water source contamination.

Reference

  • Biernbaum, J.A. 1995. Water Quality. Tips on Growing Bedding Plants. The Ohio Florists’ Association.
Image
Collecting a Water Sample (photo: Tina Smith, UMass Extension)
Image
Collecting a Water Sample (photo: Tina Smith, UMass Extension)
  • ‹ Protecting Groundwater from Contamination
  • Up
  • Water Quality for Crop Production ›
  • Printer-friendly version

Table of Contents

  • Overview of BMPs and Types of Greenhouses
  • Site Planning: Stormwater and Wastewater
  • Water: Supply and Sources
  • Protecting Groundwater from Contamination
  • Water Analysis
  • Water Quality for Crop Production
  • Irrigation Systems
  • Effects of Growing Media on Water and Nutrient Management
  • Nutrient Management
  • Soil Testing
  • Fertilizer Storage and Handling
  • Massachusetts Prohibited Plants
  • Worker Protection Standards (WPS)
  • Pesticide Storage, Handling and Disposal
  • Pesticides and Groundwater Protection
  • Pesticide Licensing
  • Integrated Pest Management
  • Pest Management: Proper Use of Pesticides
  • Disease Management
  • Plant Problem Diagnostic Service
  • Weed Management
  • Animal Damage Management
  • Organic Waste Management
  • Inorganic Waste Management
  • Energy
  • Good Agricultural Practices
  • References and Resources
  • Appendix A, Massachusetts Prohibited Plant List

Connect with UMass Extension Greenhouse Crops & Floriculture Program:

Facebook  Follow Us on Instagram  YouTube

Center for Agriculture, Food, and the Environment

 

Stockbridge Hall,
80 Campus Center Way
University of Massachusetts Amherst
Amherst, MA 01003-9246
Phone: (413) 545-4800
Fax: (413) 545-6555
ag [at] cns [dot] umass [dot] edu (ag[at]cns[dot]umass[dot]edu)

 

Civil Rights and Non-Discrimination Information

College of Natural Sciences

Login for faculty and staff

CAFE Units

Mass. Agricultural Experiment Station

UMass Extension

UMass Research and Education Center Farms

UMass Cranberry Station

Water Resources Research Center

Interest Areas

Agriculture

Commercial Horticulture

Energy

Environmental Conservation

Food Science

Nutrition

Water

Youth Development & 4-H

Services

Pesticide Education

Plant Diagnostics Laboratory

Soil and Plant Nutrient Testing Laboratory

Hot Water Seed Treatment

Water Testing / Environmental Analysis Laboratory

Projects

Conservation Assessment Prioritization System (CAPS)

Extension Risk Management/Crop Insurance Education

Mass. Envirothon

Mass. Herp Atlas

Mass. Keystone

MassWoods

North American Aquatic Connectivity Collaborative

RiverSmart

UMass Design Center in Springfield

Resources

Extension Sales Portal

Agriculture & Commercial Horticulture Resources

Community & Economic Vitality

Disaster Preparedness

Food Safety

Home Lawn & Garden

Integrated Pest Management (IPM)

Land Conservation Tools

Pollinators

Tick testing

Resources for Faculty and Staff

Extension Programs

4-H Youth Development

Agriculture

Crops, Dairy, Livestock and Equine

Fruit

Greenhouse Crops and Floriculture

Landscape, Nursery and Urban Forestry

Pesticide Education

Turf

Vegetable

Clean Energy

Climate Change

Food Science

Nutrition Education

Value-Added Food

Seal of The University of Massachusetts Amherst - 1863
©2025 University of Massachusetts Amherst · Site Policies · Accessibility